EasyManua.ls Logo

Ecolab EcoJet EcoStar 1500 - Multilink Network

Ecolab EcoJet EcoStar 1500
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
MULTILINK NETWORK
MULTILINK CABLE PUMP BOARD – MULTILINK SECTION
Shield (bare wire)
Black
BLK, SHIELD Terminal
Red RED Terminal
Cut plug from one end of the NETWORK CABLE and wire directly to the pump board. Run
the “plug end” of the NETWORK CABLE to the host computer and connect to PC
module/booster transformer as shown. Make sure MULTILINK network is properly wired or
network will not work. Color codes must be followed or USER INTERFACE can be
destroyed.