SIGNAL ONE START TIME PROGRAMMING EXAMPLE
FORMULA PROGRAMMED
START TIME
FORMULA 10 (SHEETS)
WASHER
SIGNAL TIME
1 2 Seconds
2 4 Seconds
3 6 Seconds SIGNAL 1 20 seconds
4 8 Seconds START SIGNAL
5 10 Seconds
6 12 Seconds SIGNAL 2 (1st Occ) 10 seconds
7 14 Seconds ALK, DET
8 16 Seconds
9 18 Seconds SIGNAL 3 (1st Occ) 10 seconds
10 20 Seconds BLEACH
11 22 Seconds
12 24 Seconds SIGNAL 5 (1st Occ) 10 seconds
13 26 Seconds SOUR, SOFT
14 28 Seconds
15 30 Seconds SIGNAL 5 (2nd Occ) 10 seconds
16 32 Seconds STOP SIGNAL
17 34 Seconds
18 36 Seconds
19 38 Seconds
20 40 Seconds
Signals 2 through 5 should only be programmed for 10 seconds. If more than one product signal
comes on at the same time, the appropriate product for those signal occurrences will be pumped.
To STOP a formula: program a washer signal for a second occurrence of signal 5 or (if you do not
require products 6,7,or 8) a first occurrence without product.
CHART CONTROLLED WASHERS
The EcoJet / EcoStar 1500 can interface to any wash wheel control with a chart programmer.
Standard charts or program cards that are cut for only one formula should be programmed to generate
a start signal to begin a load via the EcoJet / EcoStar 1500 Signal Interface-Signal #1 Input. To end a
load with chemical in the final rinse step, Signal #5 should be triggered twice in the last step. (Once at