WASHER SETUP – CONTINUED
AUTO FORMULA SELECT -
ECOJET / ECOSTAR 1500 ENABLED: (microprocessor mode) Signal 1 is always the
start signal in this dispenser. Click in box to have washer
microprocessor select formulas.
DISABLED: (chart mode) Formulas a manually selected at
the User Interface.
11. 5-MINUTE LOCKOUT - Protects against noise on washer signals. EcoJet / EcoStar 1500 will not respond
to a washer signal 5 minutes after receiving a signal.
12. QUALIFYING TIME - How long a signal must be on before EcoJet / EcoStar 1500 reacts to it. Default is 5
seconds. Can be programmed from 0 to 120 seconds.
13. OPERATING ZONE - This feature prevents EcoJet / EcoStar 1500 from dispensing during selected
hours. DISPENSER WILL NOT PUMP OUTSIDE OF THESE HOURS. Enter in military time. Maximum
window is from 00:00 (Midnight) to 23:59. No entry will allow pumps to be activated 24 hours.
14. AUTO FORMULA RESET – Used to enable the automatic formula termination feature. Resets formulas to
00 at the end of each load. Click in box to activate.
15. UNIT OF MEASURE - Select either U.S., Metric of Imperial.
16. ACCESS CODES - Access codes are entered at the USER INTERFACE.
17. ID NUMBER - I.D. numbers are entered at the USER INTERFACE.