USING MULTIPLE PMUs
Basic Diagram
To use PMUs in tandem, it is recommended to use CANbus 1. Both devices must be connected to
the same bus, terminated at both ends with 120 Ohm resistors. Up to five PMUs can be used at
once. For more informations regarding CAN bus see CAN Topology section.
Communication
There is no need for a special configuration per se, but for this setup to work optimally it is advised
to make use of CANbus Export and CANbus Input functionality to transmit important data between
PMUs. It is vital for those two PMUs to communicate with each other, so that proper strategies can
be set up. See CAN Stream section to find out more about CANbus communication.
Page 49