70Service Guide: EFI Fiery Central integrated server
Troubleshooting
Startup (continued)
Control panel screen
and Activity light
appear as follows:
Possibly one of the following:
Wrong, missing, incorrectly
connected, or faulty DIMM(s)
Faulty motherboard
1 Recheck all cables and connections.
2 Reboot the FC integrated server.
3 If the problem persists, verify that the DIMMs are
installed. DIMMs must be installed in matching pairs in
alternating sockets. Check for incorrect type, wrong
capacity, missing, or faulty DIMM(s). Reseat the
DIMM(s) to remove any oxidation on the connector
(see page 33).
4 If the problem persists, you may need to replace the
motherboard (see page 30).
Control panel screen
and Activity light
appear as follows:
Possibly one of the following:
Faulty disk in the DVD drive
Faulty motherboard
1 Reboot the FC integrated server.
2 If the problem occurs when you are installing software
from bootable media (DVD or CD), the media may be
damaged. Try another DVD or CD.
3 If the problem persists, replace the motherboard (see
page 30).
Table 2: FC integrated server error messages and condition (Continued)
Symptom Possible cause Suggested action
Activity light status:
Off, then solid red.
STARTING UP...
Activity light status:
Blinking orange,
then solid red.

Table of Contents

Other manuals for EFI Fiery

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EFI Fiery and is the answer not in the manual?

EFI Fiery Specifications

General IconGeneral
CategoryServer
ProcessorIntel Xeon
Operating SystemLinux
ConnectivityEthernet, USB, optional Wi-Fi
Supported PrintersVaries by model (designed to support specific printer models from various manufacturers)
SoftwareFiery Command WorkStation

Related product manuals