13.2 - ALARM CODE LIST
FAILURE
CODE
DISPLAY
OUI
DESCRIPTION
DEPENDING
ON CAVITY
SEE
PAGE
F1
F101
Door lock sensor alarm
Dependent
31
F2
F102
Door lock actuator
Dependent
31
F3
F203
Configuration checksum alarm OUI (*)
Independent
31
F94
F194
PT500 out of range warning
Dependent
31
F4
F104
PT500 out of range alarm
Independent
31
F5
F105
PT500 too high temperature alarm
Independent
31
F95
F195
NTC too high temperature alarm
Independent
32
F96
F196
NTC out of range warning
Independent
32
F6
F106
NTC out of range alarm
Independent
32
F8
F908
Communication alarm
Independent
32
F9
F109
Software compatibility code alarm
Independent
32
F92
F192
Meat probe humidity alarm
Dependent
32
F11
F111
Meat probe out of range alarm
Dependent
32
F14
F214
Configuration compatibility alarm OUI (*)
Independent
33
F15
F215
Configuration coherent alarm OUI (*)
Independent
33
F16
F716
Pyro hob alarm OUI (*)
Dependent
33
F17
F917
Hob-Oven power management alarm OUI (*)
Independent
33
F18
F718
Hob-Oven communication alarm OUI (*)
Independent
34
F21
F321
High start temperature (Smart Board) (*)
Dependent
34
F22
F322
No start temperature (Smart Board) (*)
Dependent
34
F23
F323
Invalid configuration error (Smart Board) (*)
Dependent
34
F24
F324
Unknown state Error (Smart Board) (*)
Dependent
34
F25
F325
Read flash memory error (Smart Board) (*)
Dependent
35
F26
F326
Ad calibration running error (Smart Board) (*)
Dependent
35
F27
F327
Error Unknown (Smart Board) (*)
Dependent
35
F28
F928
Smart communication alarm
(Smart Board) (*)
Dependent
35
F29
F329
ADC Board error (Smart Board) (*)
Dependent
35
F30
F130
Triac alarm
36
F31
F131
Steamer/Magnetron NTC Temperature
sensor alarm
36
F32
F132/
F232
Door lock configuration alarm OC / OUI
36
F33
F133/
F233
Data flash alarm
36
F34
F134
AD converter Reference alarm
36
F35
F135
Electronic clixon alarm
36
F36
F136
Food probe configuration alarm
37
F37
F137
Food probe communication alarm
37
F38
F138
Fix sensor detection alarm
37
F239
Quantum Touch Controller alarm OUI (*)
37
F241
Function selector not connected alarm OUI
Hexagon (*)
37
C1
(***)
Tele run at pyro function (**)
Dependent
38
C2
(***)
Meat probe at pyro function (**)
Dependent
38
C3
(***)
Opened door at pyro function (**)
Dependent
38
(*) Alarm codes concerning the user interface
(**) Warnings for the Customer
(***) This code is dependent from the user interfaces in some the indication is textual (see documentation for