Service
Manual
23
23. Programme unit
36
438 9145-41/03
03.11
1 2 3
4 5 6
7 8 9
0
Y/N
LEVEL UNBALANCE 0
LEVEL LOW 135
LEVEL MEDIUM 150
LEVEL HIGH 175
MIDDLE TEMPERATURE COOL-DOWN 70 °C
DEFAULT MOTOR ON TIME 0:12
DEFAULT MOTOR OFF TIME 0:03
FLUSH DELAY TIME 0:06
FLUSH ON TIME 0:10
BUZZER ON BUTTON Y
MAX FILLING TIME 10:00
MAX HEATING TIME 10:00
SHOW WEIGHT TIMEOUT 0:20
PC5 BLOCKING OF HEATING N
PC5 BLOCKING OF SPINNING Y
HEAT 2 AS STANDARD Y
SERVICE ALARM HOURS Y
Flush times
Here you determine times relating to flushing clean
the supply lines of an external system for liquid
detergent: the delay time and the length of time
”on”.
Key click on
Here you determine whether or not there will be an
audible click (or beep) each time a key on the PCU
control panel is pressed.
If you answer Yes (Y):
Click (beep) for each key press.
If you answer No (N):
No click or beep audible when keys pressed.
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .
Answer Yes (Y) or No (N).
Press .
LEVEL UNBALANCE 0
LEVEL LOW 135
LEVEL MEDIUM 150
LEVEL HIGH 175
MIDDLE TEMPERATURE COOL-DOWN 70 °C
DEFAULT MOTOR ON TIME 0:12
DEFAULT MOTOR OFF TIME 0:03
FLUSH DELAY TIME 0:06
FLUSH ON TIME 0:10
BUZZER ON BUTTON Y
MAX FILLING TIME 10:00
MAX HEATING TIME 10:00
SHOW WEIGHT TIMEOUT 0:20
PC5 BLOCKING OF HEATING N
PC5 BLOCKING OF SPINNING Y
HEAT 2 AS STANDARD Y
SERVICE ALARM HOURS Y