Service
Manual
37
23
23. Programme unit
438 9145-41/03
03.11
1 2 3
4 5 6
7 8 9
0
1 2 3
4 5 6
7 8 9
0
BUZZER ON BUTTON Y
MAX FILLING TIME 10:00
MAX HEATING TIME 10:00
SHOW WEIGHT TIMEOUT 0:20
PC5 BLOCKING OF HEATING N
PC5 BLOCKING OF SPINNING Y
HEAT 2 AS STANDARD Y
SERVICE ALARM HOURS Y
BUZZER TIMEOUT AT END Y
BUZZER TIMEOUT AT PAUS Y
ERROR, OVERFILLED Y
PASSWORD ACTIVE Y
CMIS ADDRESS 0
LEVEL IN MM ACTIVE Y
START SLOW FILLING, HG 10
OFFSET LEVEL, HG 2
READY
BUZZER ON BUTTON Y
MAX FILLING TIME 10:00
MAX HEATING TIME 10:00
SHOW WEIGHT TIMEOUT 0:20
PC5 BLOCKING OF HEATING N
PC5 BLOCKING OF SPINNING Y
HEAT 2 AS STANDARD Y
SERVICE ALARM HOURS Y
BUZZER TIMEOUT AT END Y
BUZZER TIMEOUT AT PAUS Y
ERROR, OVERFILLED Y
PASSWORD ACTIVE Y
CMIS ADDRESS 0
LEVEL IN MM ACTIVE Y
START SLOW FILLING, HG 10
OFFSET LEVEL, HG 2
READY
Maximum filling time
Here you determine the maximum time to be
allowed for filling the machine with water to the
level set.
If the correct level has not been reached within this
time, the error message ”NO WATER” will appear
on the display.
Maximum heating time
Here you determine the maximum time to be
allowed to heat the water a certain number of
degrees (the number of degrees can be set as a
parameter via the function ”MINIMUM
TEMPERATURE INCREASE” under ”SETTINGS
2”).
If the water has not been heated within this time,
the error message ”NO HEATING” will appear on
the display.
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .