THE MACHINE DOES NOT PRODUCE STEAM AND DOES NOT HEAT UP
THE WATER (C10 ITA
Due to the (even temporary) lack of water in the boiler the heating element safety device
may have been disactivated of the boiler.
The heating element safety device can be manually reactivated, after the reason for
the lack of water in the boiler has been eliminated or repaired .
Contact Technical Assistance.
BOILER WATER LEVEL CONTROL ALARM, FAULT (C3 ITA)
If on the main screen V1 the following alert appears: (UG10)
a major fault has occurred.
The fault could be due to:
- Fault in the boiler water inlet solenoid valve or obstruction to the passing of water
through some parts of the machine.
- Electrically isolating incrustations on the level probe or an interruption in its electrical
connection that prevents the presence of water in the boiler from being detected:
Switch off the machine and contact Technical Assistance .
BOILER TEMPERATURE CONTROL ALARM, FAULT (C11 ITA)
If on the main screen V1 the following alert appears: (UG11)
a major fault has occurred.
Switch off the machine and contact Technical Assistance .
ELECTRONIC CONTROL ALARM FAULTA)
If on the main screen V1 the following alert appears: (UG41)
It is in the presence of a serious fault in the electronic control system of the appliance or to
the electrical wiring system.
Switch off the machine and contact Technical Assistance .