2. PROJECTION LAMP (Fig. 6)
Fig. 6
REPLACEMENT
1. Pullout Lamp socket assy (Fig.6-1) from Lamp.
2. Hold the Lamp presser (Fig.6-2) of Lamp holder (2) assy and pullout Lamp.
3. To install a replacement Lamp, place the square base of Lamp into the hollow and push the
reflector into the metal rim of Lamp holder (2) assy.
4. To obtain the sufficient screen brightness, first loosen attaching screws (Fig.6-3,x4) and move
Lamp fixing plate and Lamp holder (2) assy back and forth or up and down, until most bright
and leveled screen brightness can be accomplished.
5. Screen brightness of the high position should be satisfied undermentioned specification.
Screen Center .… 800 Lx. min.
Screen Corner .… 50% of the center brightness
NOTE:
1. Do not touch inside of the Lamp reflector as well as Lamp itself.
2. Replacing Lamp, first disconnect Power cord.
3. Life of the Lamp installed is averaged 35 hours under normal projection.
4. Applied voltage to the lamp should be 14.3-15V A.C. on high position and 12.3-13V A.C. on low
position, under the lamp lighting condition.