MES53xx, MES33xx, MES23xx Ethernet Switch Series 134
The number of packets received the entry generation period, with a length of less
than 64 bytes (w/o frame bits, but with checksum bits), that have invalid checksum
with an integer number of bytes (frame check sequence validation errors, FCS) or
with a non-integer number of bytes (alignment errors).
The number of packets received the entry generation period, with a length of more
than 1518 bytes (w/o frame bits, but with checksum bits), that have invalid
checksum with an integer number of bytes (frame check sequence validation errors,
FCS) or with a non-integer number of bytes (alignment errors).
The number of detected events when the packets were dropped during the entry
generation period.
Show the alarm signal summary table:
console# show rmon alarm-table
Index OID Owner
----- -------------------------- -------
1 1.3.6.1.2.1.2.2.1.10.1 CLI
2 1.3.6.1.2.1.2.2.1.10.1 Manager
Table 5.133. Result description
Index that uniquely identifies the entry.
User that created the entry.
Show alarm events configuration with index 1:
console# show rmon alarm 1
Alarm 1
-------
OID: 1.3.6.1.2.1.2.2.1.10.1
Last sample Value: 878128
Interval: 30
Sample Type: delta
Startup Alarm: rising
Rising Threshold: 8700000
Falling Threshold: 78
Rising Event: 1
Falling Event: 1
Owner: CLI
Table 5.134. Result description
The value of the variable in the last control interval. If the default variable selection
method is absolute, the value is equal to the absolute value of the variable; if the
method is delta, it will be the difference between the variable values at the start
point and end point of the control interval.
Time interval in seconds when data is collected and compared to upper and lower
thresholds.