MES53xx, MES33xx, MES23xx Ethernet Switch Series 135
Sample Type
The method for selecting variables and calculating values to be compared with the
thresholds. absolute - the absolute value of the selected variable will be compared
to the threshold at the end point of the control interval. delta - the value of the
variable selected in the last selection will be deducted from the current value and
the difference will be compared to the thresholds (the difference between the
variable values at the start and end points of the control interval).
Startup Alarm
Event generation instruction in the first control interval. Specify alarm event
generation rules for the first control interval by comparing the selected variable
with one or both thresholds.
rising - generate a single alarm event for the rising threshold if the selected variable
value in the first control interval is above or equal to this threshold.
falling - generate a single alarm event for the falling threshold if the selected
variable value in the first control interval is below or equal to this threshold.
rising-falling - generate a single alarm event for the rising and/or falling threshold if
the selected variable value in the first control interval is above or equal to the rising
threshold/below or equal to the falling threshold.
Rising Threshold
Rising threshold value. When the selected variable value is less than the threshold in
the previous control interval and is greater or equal to threshold value in the current
control interval, a single event is generated.
Falling Threshold
Falling threshold value. When the selected variable value is greater than the
threshold in the previous control interval and is less or equal to threshold value in
the current control interval, a single event is generated.
Rising Event
Event index used when the rising threshold is crossed.
Falling Event
Event index used when the falling threshold is crossed.
Owner
User that created the entry.
Show the RMON remote monitoring event table.
console# show rmon events
Index Description Type Community Owner Last time sent
----- ----------- ---------- ---------- -------- -------------------
1 Errors Log CLINov 10 2009 18:47:17
2 High Broadcast Log-Trap router Manager Nov 10 2009 18:48:48
Table 5.135. Result description
Parameter
Description
Index
Index that uniquely identifies the event.
Description
Comment that describes the event.
Type
The type of notification generated by the device for this event:
none - do not create a notification,
log - create a table entry,
trap - send an SNMP trap,
log-trap - create table entry and send an SNMP trap.
Community
SNMP community string for trap transmission.
Owner
User that created the event.
Last time sent
Time and date of the last event generation. If no events has been generated, this
value will be equal to zero.
Show the RMON remote monitoring entry table.
console# show rmon log