EasyManua.ls Logo

ELTEX SMG-4 - Page 131

ELTEX SMG-4
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SMG digital gateway 131
Command
Parameter
Value
Action
?
Show the list of available commands
alarm
<ON_OFF>
on/off
Enable/disable fault indication for this
E1 stream
config
Return to the Configuration menu
crc4
<ON_OFF>
on/off
Enable/disable CRC4 control for this E1
stream
disabled
Disable the stream operation
enabled
Enable the stream operation
equalizer
<ON_OFF>
on/off
Enable/disable Е1 stream signal
amplification
exit
Return from this configuration submenu
to an upper level
history
Show the history of entered commands
lapd
Enter the LAPD parameters
configuration mode for this E1 stream
linecode AMI
Set the AMI linear encoding type for this
stream
linecode HDB3
Set the HDB3 linear encoding type for
this stream
name
<NAME>
63 characters max.
(numbers, letters, "_")
E1 stream name
q931
Enter the Q.931 signalling configuration
mode for the current E1 stream
quit
Terminate this CLI session
remalarm
<ON_OFF>
on/off
Enable/disable remote fault indication
for this stream
show
Show this stream configuration
signaling
Signaling type
Q931_USR Q931_NET
SS7
SORM
Set the signalling type for a stream
Possible signalling types: Q931_USR,
Q931_NET, SS7, SORM
slipIND
<ON_OFF>
on/off
Enable fault indication when slips are
identified in the reception path
slipTO
<TIMEOUT>
5sec/10sec/
20sec/30sec/
45sec/1min/
2min/3min/
5min/10min/
15min/30min/
1hour/2hour/6hour
Specify time interval for stream
parameters polling on the card; if a slip
is detected in the stream, PBX will
indicate an alarm during the timeout
ss7
Enter the configuration mode for
SS-7 signalling parameters of the current
E1 stream
4.3.8.1 LAPD Parameters Configuration Mode for the Current E1 Stream
This mode is available only for Q.931 signalling (set by the signaling command). To enter this mode,
execute the lapd command in the E1 stream configuration mode.
SMG4-[CONFIG]-E1[0]> lapd
E1[0]. Signaling is Q931
SMG4-[CONFIG]- E1[0]-[LAPD]>

Table of Contents