<CDR_ACCESS>
<LOG_ACCESS>
<MNT_ACCESS>
no_access/r/w/r
no_access/r/w/r
no_access/r/w/r
selected user:
- configure access to the CDR directory,
read/write;
- configure access to the LOG directory,
read/write;
- configure access to the MNT directory,
read/write
Change the password for the selected
user
4.3.11 SS7 Line Group Configuration Mode
To enter this mode, execute the linkset <LINKSET_INDEX> command in the configuration mode, where
<LINKSET_INDEX> is the number of a line group.
SMG4-[CONFIG]> linkset 0
Entering Linkset-mode.
SMG4-[CONFIG]-LINKSET[0]>
Show the list of available commands
Define an access category for the line
group
Enable/disable fault indication for this
SS-7 line group
Enable channel integrity check for the
SS-7 line group
Define the frequency of channel
integrity checks during outgoing calls
performed through the SS-7 line group
Send the first digit of the CdPN number
in the IAM message in the overlap
dialling mode
up_ring/
down_ring/
up_start/
down_start/
odd_up_ring/
odd_down_ring/
even_up_ring/
even_down_ring
Define the channel engagement order
for this SS-7 line group
up_ring—sequential forward;
down_ring—sequential back;
up_start—from the first and forward;
down_start—from the first and back;
odd_up_ring—sequential forward odd;
odd_down_ring—sequentially back odd;
even_up_ring—sequential forward even;
even_down_ring—sequential back even.
Enable/disable Chinese SS-7 protocol
specification support
Enable/disable the combined mode
Return to the Configuration menu
Define a code for the opposite signalling
point—DPC
Emergency phasing in case of a single
signal link in a linkset
Return from this configuration submenu
to an upper level
Show the history of entered commands