EasyManua.ls Logo

ELTEX SMG-4 - Page 167

ELTEX SMG-4
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SMG digital gateway 167
normal
level timer (x100 ms)
set mtp2 T4
emergency
<TIMER>
4-6
Set a value of MTP2 T4
emergency level timer (x100 ms)
set mtp2 T6
<TIMER>
30-60
Set a value of MTP2 T6 level
timer (x100 ms)
set mtp2 T7
normal
<TIMER>
5-20
Set a value of MTP2 T7 normal
level timer (x100 ms)
set mtp3 T2
<TIMER>
7-20
Set a value of MTP3 T2 level
timer (x100 ms)
set mtp3 T4
<TIMER>
5-12
Set a value of MTP3 T4 level
timer (x100 ms)
set mtp3 T12
<TIMER>
8-15
Set a value of MTP3 T12 level
timer (x100 ms)
set mtp3 T13
<TIMER>
8-15
Set a value of MTP3 T13 level
timer (x100 ms)
set mtp3 T14
<TIMER>
20-30
Set a value of MTP3 T14 level
timer (x100 ms)
set mtp3 T17
<TIMER>
8-15
Set a value of MTP3 T17 level
timer (x100 ms)
set mtp3 T22
<TIMER>
1800-3600
Set a value of MTP3 T22 level
timer (x100 ms)
set mtp3 T23
<TIMER>
1800-3600
Set a value of MTP3 T23 level
timer (x100 ms)
set isup T1
<TIMER>
150-600
Set a value of ISUP T1 level timer
(x100 ms)
set isup T5
<TIMER>
3000-9000
Set a value of ISUP T5 level timer
(x100 ms)
set isup T6
<TIMER>
100-600
Set a value of ISUP T6 level timer
(x100 ms)
set isup T7
<TIMER>
200-300
Set a value of ISUP T7 level timer
(x100 ms)
set isup T8
<TIMER>
150-600
Set a value of ISUP T1 level timer
(x100 ms)
set isup T9
<TIMER>
300-2400
Set a value of ISUP T9 level timer
(x100 ms)
set isup T12
<TIMER>
150-600
Set a value of ISUP T12 level
timer (x100 ms)
set isup T13
<TIMER>
3000-9000
Set a value of ISUP T13 level
timer (x100 ms)
set isup T14
<TIMER>
150-600
Set a value of ISUP T14 level
timer (x100 ms)
set isup T15
<TIMER>
3000-9000
Set a value of ISUP T15 level
timer (x100 ms)
set isup T16
<TIMER>
150-600
Set a value of ISUP T16 level
timer (x100 ms)
set isup T17
<TIMER>
3000-9000
Set a value of ISUP T17 level
timer (x100 ms)
set isup T18
<TIMER>
150-600
Set a value of ISUP T18 level
timer (x100 ms)
set isup T19
<TIMER>
3000-9000
Set a value of ISUP T19 level
timer (x100 ms)
set isup T20
<TIMER>
150-600
Set a value of ISUP T20 level
timer (x100 ms)
set isup T21
<TIMER>
3000-9000
Set a value of ISUP T21 level
timer (x100 ms)
set isup T22
<TIMER>
150-600
Set a value of ISUP T22 level
timer (x100 ms)
set isup T23
<TIMER>
3000-9000
Set a value of ISUP T23 level

Table of Contents