EasyManua.ls Logo

ELTEX SMG-4 - Page 31

ELTEX SMG-4
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SMG digital gateway 31
4.1.2.2 E1 Stream Monitoring
This section
4
contains information on the chip installed in the M4E1 submodule, as well as on E1 stream
monitoring and statistics.
M4E1 Submodule Infoinformation about chip name and identifier.
Stream Parameters
Statestream status:
WORKstream in operation;
LOSsignal lost;
OFFstream is disabled in configuration;
NONEsubmodule not installed;
AISalarm state indication signal (signal that contains all units);
LOMFmulti-frame alarm state indication signal;
RAIremote alarm indication;
D channel statusstatus of D-channel, service management channel;
upD-channel is in operation;
downD-channel is not in operation;
nothere is no management channel for the stream;
offsignalling is disabled for the stream.
D-channel state - state of D channel, service management channel
up- D-channel is in operation
down - D-channel is not in operation
no- there is no management channel for the stream
off - signalling is disabled for the stream
Statistics collection time, sectime for statistics collection in seconds.
4
Only one E1 stream is available in an SMG-2 device by default. To activate another one, a special licence is required. For
more information about licences, see section 4.1.19. Licence Renewal