nas_fs
179
The nas Commands
name = ufs3
acl = 0
in_use = False
type = rawfs
worm = off
volume = v173
pool = clar_r5_performance
member_of = root_avm_fs_group_3
rw_servers=
ro_servers=
rw_vdms =
ro_vdms =
auto_ext = no,virtual_provision=no
stor_devs = APM00042000818-001F,APM00042000818-001D,APM00042000818-0019,APM00042
000818-0016
disks = d20,d18,d14,d11
See Example #1 and Example #3 for a description of command
output. The clar_r5_performance storage pool is available with the
CLARiiON backend.
EXAMPLE #5 To create a uxfs file system named ufs4, with a size of 100 GB, using
the clar_r5_performance pool, with File-Level Retention enabled,
4096 bytes per inode, and server_3 for file system building, type:
$ nas_fs -name ufs4 -create size=100G pool=clar_r5_performance worm=enterprise
-option nbpi=4096,mover=server_3
id = 40
name = ufs4
acl = 0
in_use = False
type = uxfs
worm = enterprise
volume = v175
pool = clar_r5_performance
member_of = root_avm_fs_group_3
rw_servers=
ro_servers=
rw_vdms =
ro_vdms =
auto_ext = no,virtual_provision=no
stor_devs = APM00042000818-001F,APM00042000818-001D,APM00042000818-0019,APM00042
000818-0016
disks = d20,d18,d14,d11
See Example #1 for a description of command output. The
clar_r5_performance storage pool is available with the CLARiiON
backend.
EXAMPLE #6 To view the size of ufs1, type: