248
Celerra Network Server Command Reference Manual
The nas Commands
mountedfs =
member_of =
status :
defined = enabled
actual = mounted
Interfaces to services mapping:
See Example #6 for a description of command output.
EXAMPLE #9 To move the image of vdm_1 onto server_4, type:
$ nas_server -vdm vdm_1 -move server_4
id = 3
name = vdm_1
acl = 0
type = vdm
server = server_4
rootfs = root_fs_vdm_1
I18N mode = UNICODE
mountedfs =
member_of =
status :
defined = enabled
actual = loaded, ready
Interfaces to services mapping:
See Example #6 for a description of command output.
EXAMPLE #10 To rename a Data Mover entry from server_2 to dm2, type:
$ nas_server -rename server_2 dm2
id = 1
name = dm2
acl = 1000, owner=nasadmin, ID=201
type = nas
slot = 2
member_of =
standby = server_5, policy=auto
status :
defined = enabled
actual = online, active
See Example #4 for a description of command output.
EXAMPLE #11 To set up an access control level value of 1432 for server_2, type:
$ nas_server -acl 1432 server_2
id = 1
name = server_2
acl = 1432
type = nas
slot = 2