server_vtlu
493
The server Commands
robot revision = 1.1a
robot serial number = P8gIgqs2k5
robot device name = c1t0l0
drives = 2
drive vendor = EMCCorp
drive product = vtluDrive
drive revision = 2.2a
Where:
EXAMPLE #4 To list allof the VTLUs on server_2, type:
$ server_vtlu server_2 -tlu -list
server_2 :
id vendor product revision serial_number device_name
3 EMCCorp vtluRobot 1.1a P8gIgqs2k5 c1t0l0
Where:
EXAMPLE #5 To display the information for the VTLU on the Data Mover
identified by its’ ID, type:
$ server_vtlu server_2 -tlu -info 3
server_2 :
id = 3
slots = 256
import/export slots = 64
robot vendor = EMCCorp
robot product = vtluRobot
robot revision = 1.1a
robot serial number = P8gIgqs2k5
robot device name = c1t0l0
drives = 2
Value Definition
id unique VTLU identifier that is assigned automatically.
slots number of virtual slots in the VTLU.
import/export slotsnumber of virtual import/export slots in the VTLU.
robot vendor vendor name of the virtual robot; maximum length is eight characters.
robot product product name of the virtual robot; maximum length is 16 characters.
robot revision revision number of the virtual robot; maximum length is four characters.
robot serial numberserial number of the virtual robot that is assigned automatically.
robot device name device name of the virtual robot; only the first number, the starting chain, can be modified.
drives number of virtual drives in the VTLU.
drive vendor vendor name of the virtual drive; maximum length is eight characters.
drive product product name of the virtual drive; maximum length is 16 characters.
drive revision revision number of the virtual drive; maximum length is four characters.
Value Definition
id unique VTLU identifier that is assigned automatically.
vendor vendor name of the virtual robot; maximum length is eight characters.
product product name of the virtual robot; maximum length is 16 characters.
revision VTLU robot’s revision number; maximum length is four characters.
serial_numberVTLU serial number that is assigned automatically.
device_name the device name of the VTLU robot; only the first number, the starting chain, can be modified.