fs_dhsm
57
The fs Commands
options = useRootCred=true proto=TCP
Done
See Example #2 for a description of command output.
EXAMPLE #12 To modify the state of the Celerra FileMover connection 0 for ufs1,
type:
$ fs_dhsm -connection ufs1 -modify 0 -state disabled
ufs1:
state = enabled
offline attr = on
popup timeout = 10
backup = offline
read policy override = full
log file = on
max log size = 25MB
cid = 0
type = CIFS
secondary =
\\winserver2.nasdocs.emc.com\dhsm1\
state = disabled
read policy override = pass
write policy = full
local_server = DM102-CGE0.NASDOCS.EMC.COM
admin = nasdocs.emc.com\Administrator
wins = 172.24.102.25
cid = 1
type = NFSV3
secondary = 172.24.102.115:/export/dhsm1
state = enabled
read policy override = full
write policy = full
options = useRootCred=true proto=TCP
Done
See Example #2 for a description of command output.
EXAMPLE #13 To modify the state of the Celerra FileMover connection 1 for ufs1,
type:
$ fs_dhsm -connection ufs1 -modify 1 -state recallonly
ufs1:
state = enabled
offline attr = on
popup timeout = 10
backup = offline
read policy override = full
log file = on
max log size = 25MB

Table of Contents

Other manuals for EMC Celerra

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EMC Celerra and is the answer not in the manual?

EMC Celerra Specifications

General IconGeneral
BrandEMC
ModelCelerra
CategoryServer
LanguageEnglish

Related product manuals