Celerra Network Server Command Reference Manual
The fs Commands
cid = 0
type = CIFS
secondary = \\winserver2.nasdocs.emc.com\dhsm1\
state = enabled
read policy override = pass
write policy = full
local_server = DM102-CGE0.NASDOCS.EMC.COM
admin = nasdocs.emc.com\Administrator
wins = 172.24.102.25
cid = 1
type = NFSV3
secondary = 172.24.102.115:/export/dhsm1
state = recallonly
read policy override = full
write policy = full
options = useRootCred=true proto=TCP
Done
See Example #2 for a description of command output.
EXAMPLE #14 To delete the Celerra FileMover connections 1 and 2 for ufs1, and
specify the recall policy for any migrated files during the delete, type:
$ fs_dhsm -connection ufs1 -delete 0,1 -recall_policy
no
ufs1:
state = enabled
offline attr = on
popup timeout = 10
backup = offline
read policy override = full
log file = on
max log size = 25MB
Done
See Example #2 for a description of command output.
EXAMPLE #15 To change the state of the Celerra FileMover connection for ufs1 to
disabled, type:
$ fs_dhsm -modify ufs1 -state disabled
ufs1:
state = disabled
offline attr = on
popup timeout = 10
backup = offline
read policy override = full
log file = on
max log size = 25MB

Table of Contents

Other manuals for EMC Celerra

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EMC Celerra and is the answer not in the manual?

EMC Celerra Specifications

General IconGeneral
BrandEMC
ModelCelerra
CategoryServer
LanguageEnglish

Related product manuals