6-6
EMC Connectrix B Series DS-4900B Version 5.1 Hardware Reference Manual
DS-4900B Specifications
Environmental requirements
Table 6-3 lists the acceptable environmental ranges for both operating
and nonoperating (such as during transportation or storage)
conditions.
Table 6-3 Environmental requirements
Condition Acceptable during operation Acceptable during non-operation
Ambient
Temperature
0º to 40º C
32º to 104º F
-25º to 70º C
-13º to 158º F
Humidity 20% to 85% RH non-condensing, at
40º C (104º F) , with maximum gradient of 10% per
hour
10% to 85% RH non-condensing, at 70º C (158º F)
Altitude 0 to 3 km (10,000 feet) above sea level 0 to 12 km (40,000 feet) above sea level
Shock 20 G, 6 ms, half-sine wave 15 G, 12-18 milliseconds, trapezoid
Vibration 0.5 G, 5-500 Hz 2.0 G, 5-500 Hz
Air flow 54.02 cu ft/min (42.5 cu m/hr) None required.