EMC VNX5300 Block Installation Guide
Site requirements
Table 2 Site Requirements
Area Requirement
Power AC Power: For high availability, at least two 110 or 240 V AC circuits are required.
or
DC Power: See the requirements in
DC-Powered VNX Series Enclosures Installation
and Operation Guide.
Network Two 1-Gigabit Ethernet management connections and two customer-supplied CAT5e
or better cables.
Space Cabinet vertical space:
3U (unit) (5.25 inches, 13.3 cm) for disk processor enclosure (DPE)
1U for the standby power supply (SPS)
For each optional DAE, either 2U or 3U
Tools Slotted or Phillips screwdriver
Management Station A Windows-based computer to run the initialization, maintenance, and management
tools with:
Minimum screen resolution of 1280 x 800 and 256 colors
At least 500 MB of free space
Connection on same LAN subnet as your system if you will use it to initialize the
system
Windows Domain Controller recommended
SMTP server network connection to the VNX5300 and the management host
•JRE*
Browser* (Internet Explorer, Mozilla Firefox)
*Supported versions are listed in the release notes.
Network information The management port and login information in the Planning Worksheets of this install
guide. This information includes:
A static IP address for each storage processor in the system (for example,
123.45.6.7)
The IPv6 global prefix and gateway for each SP if your network supports the IPv6
Internet Protocol and you want to manually configure IPv6 for the management
ports
The subnet mask of the LAN to which the system is connected
The default gateway address of the LAN to which the system is connected