October 2019
Installation, Operation and Maintenance Manual
MAN-02-04-97-0713-EN Rev. 1
158
Appendix
Appendix
Table E-1.
Hazardous zone Categories according to 2014/34/EU Directive
Gas, mists, or vapors Zone 0 1G
Gas, mists, or vapors Zone 1 2G or 1G
Gas, mists, or vapors Zone 2 3G or 2G or 1G
Dust Zone 20 1D
Dust Zone 21 2D or 1D
Dust Zone 22 3D or 2D or 1D
Table E-2. Equipment Protection Level (EPL). EN 60079-14
Explosive Atmosphere Zone EPL
Gas
0 Ga
1 Ga or Gb
2 Ga or Gb or Gc
Dust
20 Da
21 Da or Db
22 Da or Db or Dc
E.3 Applicable General Standards and Regulations
Table E-3.
2006/42/EC Machinery directive
2014/30/EU EMC directive
2014/35/EU Low voltage directive
2014/34/EU ATEX directive
EN ISO 12100-1
Safety of machinery - Basic concepts,
general principles for design.
Part 1 - Basic terminology, methodology.
EN ISO 12100-2
Safety of machinery - Basic concepts,
general principles for design.
Part 2 - Technical principles and
specication.
EN 60079-0: 2012/A11:2013 IEC 60079-0: 2011
EN 60079-1: 2014 IEC 60079-1: 2014
EN 60079-7: 2015 IEC 60079-7: 2015
EN 60079-11: 2012 IEC 60079-11: 2011
EN 60079-31: 2014 IEC 60079-31: 2013
EN ISO 80079-36:2016 ISO 80079-36:2016
EN ISO 80079-37:2016 ISO 80079-37:2016
E.4 Terms and Conditions
Emerson guarantees every product to be free from defects and to conform to industry
standards. Unless otherwise specied, the warranty period is one year from the date of
installation by the rst user or eighteen months from the date of shipment to the rst user,
whichever occurs rst.
No warranty is given for products that are subject to improper storage, improper
installation, misuse, or are modied or repaired by unauthorized personnel.
Repair work resulting from improper use will be charged at standard rates.