9.3.6 Set Maintenance Date
The maintenance date routine allows the following operations:
to set the last maintenance date
to set the next maintenance date
to set the start-up date
Configuration procedure
Move the local selector to OFF and then simultaneously press OPEN and STOP.
Select the language and enter the password according to the instructions
(see “Entering the set-up mode”). When the message displayed is “SET-UP MODE
OK?” press YES. Press NO to scroll through the list of available menus and then YES
to select the "Maintenance" menu.
Press NO to scroll through the list of available routines and press YES to select
"Maintenance Date".
Press YES to set the last maintenance date. Press NO to skip to
“next maintenance date”.
Last maintenance date
Press YES if the date is correct; otherwise, press NO to change it.
Enter day, month, and year. Press NO to scroll through the list of available values;
press YES to select.
Press YES if the date is correct.
Next maintenance date
Press YES if the date is correct; otherwise, press NO to change it.
Enter day, month, and year. Press NO to scroll through the list of available values;
press YES to select.
Press YES if the date is correct.
Start-up date
Press YES if the date is correct; otherwise, press NO to change it.
Enter day, month, and year. Press NO to scroll through the list of available values;
press YES to select.
Press YES if the date is correct.