35
Installation
Figure 18: Epsilon Input/Output Wiring Diagram
The I/O connector is a 26-pin male connector on the front of the
drive. EMERSON Motion Control offers a low profile interface
plug and cable (EIO-xxx) for connections.
Drive Enable Input
10
Input #4
Input #3
Input #2
Input #1
11
1
2
12
8
Output #3
Output #2
Output #1
7
17
I/O Supply +
I/O Common -
19
20
Front View
Single point
PE ground.
-
+
24 VDC
Load
Load
Load
A highspeed diode
(such as a 1N4000) is
required for inductive
loads such as a relay,
solenoid or contactor.
I/O supply
+10 to 30 VDC
2.8 k
J3
1 Amp Fuse