EasyManua.ls Logo

Emerson ROC827 - Page 105

Emerson ROC827
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ROC800-Series Instruction Manual
Revised July-2017 Input/Output Modules 4-19
DENSITOMETER
GENERIC
-
+
+T
PI
PI
-
+
DRY CONTACT
ROC800 POWERED
+
OPEN COLLECTOR
EXTERNALLY POWERED DEVICE
OR
OPEN DRAIN TYPE
-
Figure 4-18. Generic Densitometer Wiring on APM
Figure 4-19. Input Detector Wiring on APM
DET SW 1 DET SW 2
DET SW 1 DET SW 2
Figure 4-20. Series Detector Switch (Normally
Open) Wiring on APM
Figure 4-21. Series Detector Switch Wiring
(Normally Closed) on APM
DET SW 1 DET SW 2
METER
-
+
METER
COIL 2
-
+
-
+
+T
METER
-
+
POWERED
EXTERNALLY
PREAMP
PREAMP
EXTERNALLY POWERED
+T
COIL 1
Figure 4-22. Independent Detector Wiring on APM
Figure 4-23. Two-Pulse Turbine Pulse Input Wiring
on APM

Table of Contents

Related product manuals