EasyManuals Logo

Emerson Rosemount 3051S MultiVariable Reference Manual

Emerson Rosemount 3051S MultiVariable
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
Safety messages
NOTICE
Read this manual before working with the product. For personal and system safety, and for optimum product performance make
sure you thoroughly understand the contents before installing, using, or maintaining this product.
For technical assistance, contacts are listed below:
Customer Central
Technical support, quoting, and order-related questions. United States - 1-800-999-9307
(7:00 am to 7:00 pm CST) Asia Pacific- 65 777 8211Europe/Middle East/Africa - 49 (8153) 9390
North American Response Center
Equipment service needs.
1-800-654-7768 (24 hours—includes Canada)
Outside of these areas, contact your local Emerson
representative.
CAUTION
The products described in this document are NOT designed for nuclear-qualified applications. Using non-nuclear qualified
products in applications that require nuclear-qualified hardware or products may cause inaccurate readings.For information on
Rosemount nuclear-qualified products, contact your local Emerson Sales Representative.
WARNING
Explosions could result in death or serious injury.
Installation of this transmitter in an explosive environment must be in accordance with the appropriate local, national, and
international standards, codes, and practices. Review the approvals section of this manual for any restrictions associated with a
safe
Before connecting a Field Communicator in an explosive atmosphere, ensure the instruments in the loop are installed in
accordance with intrinsically safe or non-incendive field wiring practices.
In an explosion-proof/flameproof installation, do not remove the transmitter covers when power is applied to the unit.
Process leaks may cause harm or result in death.
Install and tighten process connectors before applying pressure.
Do not attempt to loosen or remove flange bolts while the transmitter is in service.
Electrical shock can result in death or serious injury.
Avoid contact with the leads and terminals. High voltage that may be present on leads can cause electrical shock.
2

Other manuals for Emerson Rosemount 3051S MultiVariable

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Rosemount 3051S MultiVariable and is the answer not in the manual?

Emerson Rosemount 3051S MultiVariable Specifications

General IconGeneral
Accuracy±0.04% of span
Pressure RangeUp to 4000 psi (276 bar)
Communication ProtocolsHART, FOUNDATION Fieldbus, PROFIBUS PA
Ambient Temperature Limit-40 to 85 °C (-40 to 185 °F)
Power Supply (Fieldbus)9-32 VDC
Measurement TypeTemperature, Flow
Output4-20 mA HART, FOUNDATION Fieldbus
Temperature Range-40 to 85°C (-40 to 185°F)
Material316L SST, Hastelloy, Monel
ServiceLiquid, gas, steam
Warranty5 years
Measurement Range0-4000 psi
Process Temperature Limit-40 to 120°C (-40 to 248°F)
DiagnosticsAdvanced diagnostics
Certifications/ApprovalsFM, CSA, ATEX, IECEx, SIL 2/3
Process Connection1/2-14 NPT
Electrical Connection1/2-14 NPT, M20
Enclosure RatingIP66, NEMA 4X
Stability±0.1% of URL per 5 years