3.5 Rosemount 305 and 304 Manifolds
The Rosemount 305 Integral Manifold is available in two designs: coplanar and traditional.
The traditional Rosemount 305 can be mounted to most primary elements with mounting
adapters.
Rosemount 305 Integral Coplanar Rosemount 305 Integral Traditional
The Rosemount 304 comes in two basic styles: traditional (flange X flange and flange X
pipe) and wafer. The Rosemount 304 Traditional Manifold comes in 2-, 3-, and 5-valve
configurations. The Rosemount 304 Wafer Manifold comes in 3- and 5-valve
configurations.
Rosemount 304 Traditional
Rosemount 304 Wafer
Reference Manual Installation
00809-0100-4803 October 2018
Emerson.com/Rosemount 91

Other manuals for Emerson Rosemount 3051S MultiVariable

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Rosemount 3051S MultiVariable and is the answer not in the manual?

Emerson Rosemount 3051S MultiVariable Specifications

General IconGeneral
Accuracy±0.04% of span
Pressure RangeUp to 4000 psi (276 bar)
Communication ProtocolsHART, FOUNDATION Fieldbus, PROFIBUS PA
Ambient Temperature Limit-40 to 85 °C (-40 to 185 °F)
Power Supply (Fieldbus)9-32 VDC
Measurement TypeTemperature, Flow
Output4-20 mA HART, FOUNDATION Fieldbus
Temperature Range-40 to 85°C (-40 to 185°F)
Material316L SST, Hastelloy, Monel
ServiceLiquid, gas, steam
Warranty5 years
Measurement Range0-4000 psi
Process Temperature Limit-40 to 120°C (-40 to 248°F)
DiagnosticsAdvanced diagnostics
Certifications/ApprovalsFM, CSA, ATEX, IECEx, SIL 2/3
Process Connection1/2-14 NPT
Electrical Connection1/2-14 NPT, M20
Enclosure RatingIP66, NEMA 4X
Stability±0.1% of URL per 5 years