EasyManua.ls Logo

Emerson Rosemount - Bappendix B: Product Certifications; Approved Manufacturing Locations; European Directive Information

Emerson Rosemount
252 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference Manual
00809-0100-4021, Rev GC
Appendix B: Product Certifications
April 2014
217
Product Certifications
Appendix B Product Certifications
Approved Manufacturing Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 217
European Directive Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 217
Ordinary Location Certification from FM Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 217
Installation Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 226
B.1 Approved Manufacturing Locations
Rosemount Inc. – Chanhassen, Minnesota, USA
Rosemount Temperature GmbH – Germany
Emerson Process Management Asia Pacific – Singapore
B.2 European Directive Information
A copy of the EC Declaration of Conformity can be found at the end of the Quick Start Guide. The
most recent revision of the EC Declaration of Conformity can be found at www.rosemount.com.
B.3 Ordinary Location Certification from FM
Approvals
As standard, the transmitter has been examined and tested to determine that the design meets
the basic electrical, mechanical, and fire protection requirements by FM Approvals, a nationally
recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety and Health
Administration (OSHA).
North America
E5 FM Explosionproof, Dust-Ignitionproof, and Nonincendive
Certificate: 3012752
Standards Used: FM Class 3600: 1998, FM Class 3611: 2004, FM Class 3615: 1989, FM
Class 3810: 2005, NEMA-250: 1991, ANSI/ISA 60079-0: 2009, ANSI/ISA 60079-11: 2009
Markings: XP CL I, DIV 1, GP A, B, C, D; T5(–50 °C
T
a
85 °C); DIP CL II/III, DIV 1, GP E, F,
G; T5(–50 °C
T
a
75 °C); T6(–50 °C T
a
60 °C); when installed per Rosemount
drawing 03144-0320; NI CL I, DIV 2, GP A, B, C, D; T5(–60 °C
T
a
75 °C); T6(–60 °C T
a
50 °C); when installed per Rosemount drawing 03144-0321, 03144-5075;
I5 FM Intrinsic Safety and Nonincendive
Certificate: 3012752
Standards Used: FM Class 3600: 1998, FM Class 3610: 2010, FM Class 3611: 2004, FM
Class 3810: 2005, NEMA-250: 1991, ANSI/ISA 60079-0: 2009, ANSI/ISA 60079-11: 2009
Markings: IS CL I / II / III, DIV 1, GP A, B, C, D, E, F, G; T4 (–60 °C
T
a
60 °C); IS [Entity] CL
I, Zone 0, AEx ia IIC T4(–60 °C
T
a
60 °C); NI CL I, DIV 2, GP A, B, C, D; T5(–60 °C T
a

75 °C); T6(–60 °C T
a
50 °C); when installed per Rosemount drawing 03144-0321,
03144-5075;

Table of Contents

Other manuals for Emerson Rosemount