DATE: The unit shows current date (day.month.year).
TIME: The unit shows current time (hour.minute.second).
HOUSE:
If TEMPERATURE SETTINGS PAGE SENS OPENING parameter is ROOM1;
HOUSE = ROOM1 sensor’s reading temperature value,
If TEMPERATURE SETTINGS PAGE SENS OPENING parameter is ROOM2;
HOUSE = ROOM2 sensor’s reading temperature value,
If TEMPERATURE SETTINGS PAGE SENS OPENING parameter is ROOM1&2;
HOUSE =( ROOM1 sensor’s reading temperature value + ROOM2 sensor’s reading temperature value) / 2.
ROOM1: Temperature that is reading from ROOM1 sensor.
ROOM2: Temperature that is reading from ROOM2 sensor.
OUT: Temperature that is reading from OUTSIDE sensor.
HUMIDITY: Humidity that is reading from HUMIDITY sensor.
FEEDING: Silo feed amount that is reading from FEEDING sensor.
DAY: Day number. PROCESS VALUES PAGE DAY, SET VALUES PAGE DAY are the same parameters.
PROCESS VALUES PAGE DAY parameter is a read-only parameter.
CURVE: If curve mode is enabled then “CURVE” word is seen.
19.07.06 14:30:21
HOUSE 20.2°C
OUT 12.1°C
HUMIDITY 65%
DAY -5 CURVE
5.4.1 PROCESS VALUE
19.07.06 14:30:21
HOUSE 20.2°C
OUT 12.1°C
FEEDING 0KG
DAY -5 CURVE
19.07.06 14:30:21
HOUSE 20.2°C
ROOM1 20.2°C
ROOM2 30.4°C
HUMIDITY 65%
DAY -5 CURVE
When the EPC is energized first PROCESS VALUES page is seen.
PROCESS VALUES page has four different screens. All screens are seen below;
CONTROL FUNC PAGE 1 PAGE HUMIDITY parameter is disabled,
CONTROL FUNC PAGE 1 PAGE OUTSIDE TEMP parameter is enabled.
(EPC3 and EPC4 feature)
CONTROL FUNC PAGE 1 PAGE HUMIDITY parameter is enabled,
CONTROL FUNC PAGE 1 PAGE OUTSIDE TEMP parameter is disabled.
19.07.06 14:30:21
HOUSE 20.2°C
ROOM1 22.4°C
ROOM2 20.2°C
FEEDING 0KG
DAY -5 CURVE
CONTROL FUNC PAGE 1 PAGE HUMIDITY parameter is disabled,
CONTROL FUNC PAGE 1 PAGE OUTSIDE TEMP parameter is disabled.
(EPC3 and EPC4 feature)
CONTROL FUNC PAGE 1 PAGE HUMIDITY parameter is enabled,
CONTROL FUNC PAGE 1 PAGE OUTSIDE TEMP parameter is enabled.
5.4 SCREENS, PARAMETERS AND FUNCTIONS
22