CURVE: Curve working activation parameter
(Range: DISABLE, ENABLE / Factory Setting: DISABLE).
HUMIDITY: Humidity input activation parameter
(Range: DISABLE, ENABLE / Factory Setting: ENABLE).
OUTSIDE TEMP: Outside sensor activation parameter
(Range: DISABLE, ENABLE / Factory Setting: ENABLE).
COMMUNICATE: Modbus communication activation parameter
(Range: DISABLE, ENABLE / Factory Setting: ENABLE).
LOAD DEFAULT: Factory default loading selection parameter
(Range: NO, YES / Factory Setting: NO).
To load factory default parameters;
Change CONTROL FUNC PAGE 1 PAGE LOAD DEFAULT parameter to YES and
change page to the other page,
EPC will change parameters to factory defaults and
EPC will change CONTROL FUNC PAGE 1 PAGE LOAD DEFAULT parameter to NO.
WATER CONSUM: Water consumption pages & features activation parameter
(Range: DISABLE, ENABLE / Factory Setting: ENABLE). (EPC 4 FEATURE)
ELECT CONSUM: Electricity consumption pages & features activation parameter
(Range: DISABLE, ENABLE / Factory Setting: ENABLE). (EPC 4 FEATURE)
CONTROL FUNC PAGE 1
CURVE : DISABLE
HUMIDITY : ENABLE
OUTSIDE TEMP: ENABLE
COMMUNICATE : ENABLE
LOAD DEFAULT: NO
WATER CONSUM: ENABLE
ELECT CONSUM: ENABLE
6.4.9 CONTROL FUNC PAGE 1
FEEDING: Feeding pages & features activation parameter
(Range: DISABLE, ENABLE / Factory Setting: DISABLE).
INPUT 1: Weigh1 activation or assigment this input as CO2 (EPC4 FEATURE) parameter
(Range: DISABLE, NH3 / Factory Setting: DISABLE).
INPUT 2: Weigh2 activation or assigment this input as CO2 (EPC4 FEATURE) parameter
(Range: DISABLE, CO2 / Factory Setting: DISABLE).
INPUT 3: Weigh3 pages & features activation parameter
(Range: DISABLE, ENABLE / Factory Setting: DISABLE). (EPC 4 FEATURE)(Not in EPC 4A)
ALARM 1: Assignment Alarm 1 input to general alarm or power cut.
(Range: ALARM - PWR / Factory Setting: ALARM).
LIGHTING: Lighting pages & features activation parameter
(Range: DISABLE, ENABLE / Factory Setting: DISABLE).
LIGHT CONT: Lighting working mode selection parameter
(Range: ON/OFF, MODULATE / Factory Setting: MODULATE).
CONTROL FUNC PAGE 2
FEEDING : ENABLE
INPUT 1 : WEIG
INPUT 2 : WEIG
INPUT 3 : WEIG
ALARM 1 : ALARM
LIGHTING : ENABLE
LIGHT CONT: MODULATE
6.4.10 CONTROL FUNC PAGE 2
63
CONTROL FUNC PAGE 1
CURVE : DISABLE
HUMIDITY : ENABLE
OUTSIDE TEMP: ENABLE
COMMUNICATE : ENABLE
LOAD DEFAULT: NO
EPC 4 EPC 3
EPC 4 EPC 3
CONTROL FUNC PAGE 2
FEEDING : ENABLE
INPUT 1 : ENABLE
INPUT 2 : ENABLE
ALARM 1 : PWR
LIGHTING : ENABLE
LIGHT CONT: MODULATE