UNIT: WEIGHT or TIME mode is used for feeding control depend on this parameter selection
(Range: WEIGHT- TIME / Factory Setting: WEIGHT).
FEED PER MIN: Feed consumption per minute (using when UNIT parameter is selected TIME)
(Range: 0.0 KG - 100.0 KG / Factory Setting: 1.0 KG).
TARE: Tare function
(Range: NO - YES / Factory Setting: NO).
REF WEIGHT: Reference weight parameter for make weight adjustment
(Range: 0 KG - 30000 KG / Factory Setting: 250 KG).
TAKE REF WEIGHT: Reading Weigh is equal to REF WEIGHT
(Range: NO - YES / Factory Setting: NO).
FEED OFFSET: Feeding amount step values are changed as feed offset value
(Range: -100 KG - 100 KG / Factory Setting: 0 KG).
FEED UNIT PARAMETERS
UNIT : TIME
FEED PER MIN: 6.0KG
TARE : NO
REF WEIGHT : 250KG
TAKE REF WEIGHT: NO
FEED OFFSET : 0KG
6.4.12.1 FEED UNIT PARAMETERS
6.4.12 FEEDING (EPC 3&4)