HR:MN (START TIME COLUMN): Step start time
(Range:00:00 - 23:59 / Factory Setting: 00:00).
HR:MN (DURATION COLUMN): Step duration
(Range:00:00 - 23:59 / Factory Setting: 00:00).
OUT% (ANALOG OUTPUT COLUMN): Analog lighting output
(Range:0% - 100% / Factory Setting: 0%).
Push button to access to ALARM SET VALUES PAGE (If no parameter is selected)
Push button to access to PROCESS VALUES PAGE (If no parameter is selected)
Push button to change parameter (If no parameter is selected)
Push button to access to SET VALUES PAGE (If the last parameter is selected)
5.4.10 LIGHTING PARAMETERS (EPC 3&4)
LIGHTING PARAMETERS
L1: 00:00 00:00 0%
L2: 00:00 00:00 0%
L3: 00:00 00:00 0%
L4: 00:00 00:00 0%
L5: 00:00 00:00 0%
HR:MN HR:MN OUT%
Start Time Duration Analog
Output
Using of LIGHTING PARAMETERS PAGE is explained in details at Technician Section.
ALARM SET VALUES
ABSOLUTE MIN: 0.0°C
ABSOLUTE MAX: 99.0°C
DIFFERENTIAL: 0.0°C
TYPE :NONLATCH
ABSOLUTE MIN: Absolute minimum alarm set value
(Range: 0.0 °C - 50.0 °C / Factory Setting: 16.0 °C).
ABSOLUTE MAX: Absolute maximum alarm set value
(Range: 0.0 °C - 99.9 °C / Factory Setting: 38.0 °C).
DIFFERENTIAL: Differential alarm set value (Range: 0.0 °C - 25.0 °C / Factory Setting: 6.0 °C).
TYPE: Alarm type set value (Range: NONLATCH- LATCH- CYCLIC / Factory Setting: NONLATCH).
5.4.11.1 ALARM SET VALUES
5.4.11 ALARMS
29