5. Influence negative pressure input on ventilation and shutter:
Negative pressure influence affects to reduce ventilation up to minimum ventilation. Also it set shutter to
maximum value. As long as INFLUENCE 2 PAGE NEG PRESSURE parameter is different from NON,
negative pressure is enabled. Otherwise negative pressure influence is disabled.
Briefly(it is assumed that negative pressure is active);
- INFLUENCE 2 PAGE NEG PRESSURE is “NON”
influence is disabled,
ventilation and shutter will not change
- INFLUENCE 2 PAGE NEG PRESSURE is anything but “NON”
influence is enabled,
ventilation = ventilation - INFLUENCE 2 PAGE NEG PRESSURE
shutter = shutter’s maximum value
INFLUENCE 2 PAGE
NEG.PRE.TOFF
INFLUENCE 2 PAGE
NEG.PRE.TON
ON
OFF
ON
OFF
Time[sec]
Time[sec]
NEG
PRESSURE
INPUT
NEG
PRESSURE
INFLUENCE
DATE SETUP
YEAR : 2006
MONTH : 1
DAY : 24
HOUR : 16
MINUTE : 31
SECOND : 36
YEAR: Current year set value (Range: 0- 99 / Factory Setting: Current year).
MONTH: Current month set value (Range: 1- 12 / Factory Setting: Current month).
DAY: Current day set value (Range: 1- 31 / Factory Setting: Current day).
HOUR: Current hour set value (Range: 0- 23 / Factory Setting: Current hour).
MINUTE: Current minute set value (Range: 0- 59 / Factory Setting: Current minute).
SECOND: Current second set value (Range: 0- 59 / Factory Setting: Current second).
5.4.17 DATE SETUP