5.4.18.4 CURVE FUNCTION
CURVE SETUP
CURVE STEP: 1
DAY : 1
HOUSE TEMP: 0.0°C
MIN. VENT : 0%00
MAX. VENT : 8%00
HUMIDITY : 80%
3. Programming a curve:
There are 10 steps for programming curve.
A CURVE SETUP PAGE DAY parameter value has to be higher than previous step’s CURVE SETUP PAGE
DAY parameter value.
If CURVE MODE CURVE parameter is DISABLE then curve is disabled. It means that even if SET VALUES
PAGE DAY is between CURVE SETUP PAGE DAY(Step1) and CURVE SETUP PAGE DAY(Step10),
curve doesn’t work.
If CURVE MODE CURVE parameter is ENABLE settemp(NOTE1), minimum and maximum ventilations,
humidity, feeding, lighting values are calculated by EPC depend on SET VALUES PAGE DAY and curve.
Example;
CURVE MODE CURVE parameter is ENABLE. The parameter values are given in graphic below;
12. day is between Step3 and Step4. So 12. day; Settemp(NOTE1) is 22 °C
2. Changing of SET VALUES PAGE DAY parameter:
SET VALUES PAGE DAY parameter can be changed in two ways.
- SET VALUES PAGE DAY increases 1 each night at 24:00 hrs.
- SET VALUES PAGE DAY can be changed from SET VALUES PAGE.
NOTE1:
If curve is enabled;
Settemp= HOUSE TEMP from curve.
Min.Vent= MIN. VENT from curve.
Max.Vent=MAX. VENT from curve.
If curve is disabled;
Settemp= SET VALUES PAGE TEMP.HOUSE.
Min.Vent= SET VALUES PAGE VENT. MIN.
Max.Vent= SET VALUES PAGE VENT. MAX.
20
Settemp[°C]
(NOTE1)
Step1 Day=1
Step2 Day=8
Step3 Day=10
Step4 Day=14
Step5 Day=20
Step6 Day=30
Step7 Day=32
Step8 Day=36
Step9 Day=38
Step10 Day=40
24
Day=12
22
Day=-5
1. What is a curve:
Optimal temperature, ventilation, humidity, feeding and lighting values change
day by day. EPC can automaticly adjust optimal values depend on entered
parameters which are in CURVE SETUP PAGES. This function is called “curve”.
CONTROL FUNC PAGE 1
CURVE : DISABLE
HUMIDITY : ENABLE
OUTSIDE TEMP: ENABLE
COMMUNICATE : ENABLE
LOAD DEFAULT: NO
WATER CONSUM: ENABLE
ELECT CONSUM: ENABLE
Day
Day=999
42
(EPC 4)