EMKO TRANS-AMF - Operator Parameters; Mains Voltage Level Settings; Mains Frequency Level Settings; Generator Voltage Level Settings

EMKO TRANS-AMF
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
600
60
60
60
600
600
600
VV
VV
VV
VV
60
Min
DefaultMAINS VOLT LEVEL (Mains->Volt level)
Max
Mains Under Voltage
Mains Under Voltage Reset
Mains Over Voltage
Mains Over Voltage Reset
320
340
440
420
Under volt trip
4.1 Operator Parameters
Under volt reset
Over volt trip
Over volt reset
Unit
25
Note: dis = disable
4. Parameters
Min
DefaultMAINS FREQ. LEVEL (Mains->Frequency level)
Max
Mains Under Frequency
Hz
Hz
Hz
Hz
20.0 75.0
20.0 75.0
20.0 75.0
20.0 75.0
45.0
48.0
55.0
52.0
Mains Under Frequency Reset
Mains Over Frequency
Mains Over Frequency Reset
Under freq trip
Under freq reset
Over freq trip
Over freq reset
Unit
600
60(dis)
60
60
600
600
600
VV
VV
VV
VV
60(dis)
Min
Default
Max
Generator Under Voltage Shutdown
Generator Under Voltage Pre-Alarm
Generator Under Voltage Pre-Alarm Reset
Generator Over Voltage Shutdown
Generator Over Voltage Pre-Alarm
320
340
350
440
60(dis) 600
60 600
420
400
Generator Over Voltage Pre-Alarm Reset
VV
VV
Under volt shutdown
Under volt prealarm
Under volt reset
Over volt shutdown
Over volt prealarm
Over volt reset
Unit
Shutdown delay time
Generator Voltage Shutdown Delay Time
GENERATOR VOLT LEVEL (Generator->Volt level)
0.0 10.0 1.0
Sec
75.0
30.0(dis)
75.0
75.0
Hz
30.0(dis)
Min
Default
Max
Generator Under Frequency Pre-Alarm
Generator Under Frequency Pre-Alarm Reset
Generator Over Frequency Shutdown
Generator Over Frequency Pre-Alarm
Generator Over Frequency Pre-Alarm Reset
45.0
46.0
58.0
55.0
54.0
Generator Frequency Shutdown Delay Time
Hz
Hz
Hz
Hz
30.0
30.0(dis)
30.0
75.0
75.0
Under freq prealarm
Under freq reset
Over freq shutdown
Over freq prealarm
Over freq reset
Shutdown delay time
Unit
GENERATOR FREQ LEVEL (Generator->Frequency level)
75.0
75.0
Hz
30.0
Nominal Alternator Frequency
50.0
43.0
Hz
Nominal frequency
Under freq shutdown
Generator Under Frequency Shutdown
30.0(dis)
0.0 10.0 1.0
Sec
Min
Default
Max
Generator Under Current Pre-Alarm Reset
Generator Over Current IDMT Alarm
Generator Over Current Set
Generator Over Current Pre-Alarm
Generator Over Current Pre-Alarm Reset
Under cur. reset
Over cur. IDMT alarm
Over cur. set
Over cur. prealarm
Over cur. reset
Unit
GENERATOR CUR LEVEL (Generator->Current level)
Generator Under Current Set
Under cur. set
Under cur. prealarm
Generator Under Current Pre-Alarm
0 9999 9980
AV
0
0(dis)
0
0
0(dis)
9999
9999
9999
9999
9999
1
dis
5
DISBL
9999
9990
AV
AV
AV
AV
AV
4.1.1 Mains
4.1.2 Generator
ENABL/DISBL