Cerabar M, Deltabar M, Deltapilot M Commissioning with the FF configuration program
Endress+Hauser 181
Sensor Serial Number/
SENSOR_SN
Display
Index: 22
Data type: visible string
Access: read only
Displays the serial number of the sensor (11 alphanumeric characters).
Sensor Calibration
Method/SENSOR_CAL_
METHOD
Options
Index: 23
Data type: unsigned8
Access: OOS
For displaying and selecting the last sensor calibration mode used.
Sensor Calibration
Location/
SENSOR_CAL_LOC
Entry
Index: 24
Data type: visible string
Access: OOS
Enter the place the sensor was calibrated (32 alphanumeric characters).
Sensor Calibration
Date/
SENSOR_CAL_DATE
Entry
Index: 25
Data type: date
Access: OOS
Enter the date and time the sensor was calibrated.
Sensor Calibration
Who/
SENSOR_CAL_WHO
Entry
Index: 26
Data type: visible string
Access: OOS
Enter the name of the person who calibrated the sensor (32 alphanumeric characters).
Sensor Isolator Metal/
SENSOR_ISOLATOR_
MTL
Display
Index: 27
Data type: unsigned16
Access: read only
Displays the material of the process isolating diaphragm.
Sensor Fill Fluid/
SENSOR_FILL_FLUID
Display
Index: 28
Data type: unsigned16
Access: read only
Displays the filling medium.