EasyManua.ls Logo

Endress+Hauser Deltabar S FMD 77 - Page 56

Endress+Hauser Deltabar S FMD 77
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Deltabar S
56 Endress+Hauser
PMD 75 (continued)
For continuation of PMD 75 ordering information, see the following page.
40 Measuring cell, nominal operating range, PN
7B 4 inH
2
O measuring cell, PN 160 (10 mbar/1 kPa/100 mmH
2
O/0.15 psi)
7C 12 inH
2
O measuring cell, PN 160 (30 mbar/3 kPa/300 mmH
2
O/0.45 psi)
7D 40 inH
2
O measuring cell, PN 160 (100 mbar/10 kPa/1 mH
2
O/1.5 psi)
7F 200 inH
2
O measuring cell, PN 160 (500 mbar/50 kPa/5 mH
2
O/7.5 psi)
7H 1200 inH
2
O measuring cell, PN 160 (3 bar/300 kPa/30 mH
2
O/45 psi)
7L 240 psi measuring cell, PN 160 (16 bar/1.6 MPa/160 mH
2
O/528 ftH
2
O)
7M 600 psi measuring cell, PN 160 (40 bar/4 MPa/400 mH
2
O/1320 ftH
2
O)
8F 200 inH
2
O measuring cell, PN 420 (500 mbar/50 kPa/5 mH
2
O/7.5 psi)
8H 1200 inH
2
O measuring cell, PN 420 (3 bar/300 kPa/30 mH
2
O//45 psi)
8L 240 psi measuring cell, PN 420 (16 bar/1.6 MPa/160 mH
2
O/528 ftH
2
O)
8M 600 psi measuring cell, PN 420 (40 bar/4 MPa/400 mH
2
O/1320 ftH
2
O)
50 Calibration, units
1 Calibration: nominal range, mbar/bar
2 Calibration: nominal range, kPa/MPa
3 Calibration: nominal range, mmH
2
O/mH
2
O
4 Calibration: nominal range, in H
2
O/ftH
2
O
6 Calibration: nominal range, psi
B Custom calibration: see additional specification
C Factory calibration: see additional specification, Factory calibration certificate, 5-point
D DKD calibration: see additional specification, DKD-Certificate
K Calibration: see additional specification, PLATINUM
L Factory calibration: see additional specification, PLATINUM,
Factory calibration certificate, 5-point
M DKD calibration: see additional specification. PLATINUM, DKD-Certificate
60 Material diaphragm
1 AISI 316L
2Alloy C
3Monel
5Tantalum
6 AISI 316L with Rhodium-Gold coating
70 Process connection, material
B 1/4 "– 18 NPT IEC 61518, mounting: 7/16" – 20 UNF, C22.8
C 1/4" – 18 NPT IEC 61518, mounting: 7/16" – 20 UNF, C22.8, side vent, including 4
fastening bolt connections (AISI 316L) mounted
D 1/4" – 18 NPT IEC 61518, mounting: 7/16" – 20 UNF, AISI 316L
E 1/4" – 18 NPT IEC 61518, mounting: 7/16" – 20 UNF, AISI 316L, side vent, including
4 fastening bolt connections (AISI 316L) mounted
F 1/4" – 18 NPT IEC 61518, mounting: 7/16" – 20 UNF, Alloy C, without screws/vents
H 1/4" – 18 NPT IEC 61518, mounting: 7/16" – 20 UNF, Alloy C, side vent, without
screws/vent
U RC 1/4 mounting: 7/16" – 20 UNF, AISI 316L
V RC 1/4 mounting: 7/16" – 20 UNF, C22.8, side vent, including 4 fastening bolt
connections (AISI 316L) mounted
W Prepared for diaphragm seal mount
1 1/4" – 18 NPT, mounting: PN 160: M10, PN 420: M12, C22.8
2 1/4" – 18 NPT, mounting: PN 160: M10, PN 420: M12, AISI 316L
3 1/4" – 18 NPT, mounting: PN 160: M10, PN 420: M12, Alloy C
80 Gasket material
A FKM Viton cell seal
C PTFE cell seal
F NBR cell seal
K Copper ring seal, cleaned for oxygen service
1 FKM Viton cell seal, degreased
2 FKM Viton seal, cleaned for oxygen service
3 PTFE seal, cleaned for oxygen service
H Copper ring seal, diaphragm seal mount
PMD 75 complete order code