Cerabar S/Deltabar S/Deltapilot S FOUNDATION Fieldbus Parameter description (Local operation and FieldCare)
Endress+Hauser 181
NORM FLOW UNIT (661)
Selection
Select the norm volume flow unit.
When a new flow unit is selected, all flow-specific parameters are converted and
displayed with the new unit within a flow mode (FLOW-MEAS. TYPE). When the flow
mode is changed, conversion is not possible.
Prerequisite:
FLOW-MEAS. TYPE = Gas norm conditions
Options:
Nm3/s, Nm3/min, Nm3/h, Nm3/day
•User unit, see also this table, parameter description for CUSTOMER UNIT F and
CUST. UNIT. FACT. F
!
Note!
Following a change in the unit, the digital output value of the Analog Input value OUT
and the local operation or the MEASURED VALUE no longer display the same value.
See also parameter descriptions for XD SCALE, OUT SCALE and OUT value.
Factory setting:
Nm
3
/s
STD. FLOW UNIT (660)
Selection
Select the standard volume flow unit.
When a new flow unit is selected, all flow-specific parameters are converted and
displayed with the new unit within a flow mode (FLOW-MEAS. TYPE). When the flow
mode is changed, conversion is not possible.
Prerequisite:
FLOW-MEAS. TYPE = Gas std. conditions
Options:
Sm3/s, Sm3/min, Sm3/h, Sm3/day
SCFS, SCFM, SCFH, SCFD
•User unit, see also this table, parameter description for CUSTOMER UNIT F and
CUST. UNIT. FACT. F
!
Note!
Following a change in the unit, the digital output value of the Analog Input value OUT
and the local operation or the MEASURED VALUE no longer display the same value.
See also parameter descriptions for XD SCALE, OUT SCALE and OUT value.
Factory setting:
Sm
3
/s
MASS FLOW UNIT (571)
Selection
Select the mass flow unit.
When a new flow unit is selected, all flow-specific parameters are converted and
displayed with the new unit within a flow mode (FLOW-MEAS. TYPE). When the flow
mode is changed, conversion is not possible.
Prerequisite:
FLOW-MEAS. TYPE = Mass p. cond.
Options:
g/s, kg/s, kg/min, kg/min, kg/h
t/s, t/min, t/h, t/day
•oz/s, oz/min
lb/s, lb/min, lb/h
ton/s, ton/min, ton/h, ton/day
•User unit, see also the following parameter descriptions for CUSTOMER UNIT F
and CUST. UNIT. FACT. F
!
Note!
Following a change in the unit, the digital output value of the Analog Input value OUT
and the local operation or the MEASURED VALUE no longer display the same value.
See also parameter descriptions for XD SCALE, OUT SCALE and OUT value.
Factory setting:
kg/s
Table 14: OPERATING MENU SETTINGS BASIC SETUP "Flow"
Parameter name Description

Table of Contents

Other manuals for Endress+Hauser Deltabar S PMD75

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Deltabar S PMD75 and is the answer not in the manual?

Endress+Hauser Deltabar S PMD75 Specifications

General IconGeneral
BrandEndress+Hauser
ModelDeltabar S PMD75
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals