Cerabar S/Deltabar S/Deltapilot S FOUNDATION Fieldbus Parameter description of local operation and FieldCare
Endress+Hauser 7
2 Parameter description of local operation and
FieldCare
You can find the parameter description as follows:
• Via the ID number for the local operation
• Via the parameter name for FieldCare
ID number Parameter name Description, see page
001 DENSITY UNIT 152 or 184
003 HEIGHT UNIT 152
004 FULL CALIB. – QUICK SETUP 140
004 FULL CALIB. – "Level easy pressure" level selection 149
004 FULL CALIB. – "Level easy height" level selection 153
005 FULL PRESSURE 149
006 FULL HEIGHT 154
007 ADJUST DENSITY 152 or 184
008 CALIBRATION MODE – "Level easy pressure" level selection 148
008 CALIBRATION MODE – "Level easy height" level selection 152
009 EMPTY HEIGHT 153
010 EMPTY CALIB. – QUICK SETUP 139
010 EMPTY CALIB. – "Level easy pressure" level selection 148 or 149
010 EMPTY CALIB. – "Level easy height" level selection 153
011 EMPTY PRESSURE 149
014 DOWNLOAD SELECT 205
020 LEVEL SELECTION 135
023 OUTPUT UNIT – "Level easy pressure" level selection 148
023 OUTPUT UNIT – "Level easy height" level selection 152
025 PROCESS DENSITY 184
046 ALARM STATUS 207
047 ENTER RESET CODE 205
048 INSERT PIN NO 205
050 LEVEL BEFORE LIN 202
060 PRESS. ENG. UNIT 144, 147, 151, 155 or 179
075 CUSTOMER UNIT P 144, 147, 151, 156 or 179
079 LANGUAGE 133
247 DAMPING VALUE 137, 140, 141, 145, 149, 154, 165,
168, 177 or 182
250 SENSOR SER. No. 198
264 SOFTWARE VERSION 196
266 HARDWARE REV. 196
301 PRESSURE – "Pressure" measuring mode 201
PRESSURE – "Level" measuring mode 201
PRESSURE – "Flow" measuring mode 202
311 MAX. FLOW 141 or 182
313 UNIT VOLUME – "Linear" level mode 159 or 162
UNIT VOLUME – "Pressure linearized" level mode 166
UNIT VOLUME – "Height linearized" level mode 171
314 EMPTY CALIB. – QUICK SETUP 139
EMPTY CALIB. – "Linear" level mode 161
EMPTY CALIB. – "Height linearized" level mode 174
315 FULL CALIB. – QUICK SETUP 140
FULL CALIB. – "Pressure linearized" level mode 161
FULL CALIB. – "Height linearized" level mode 174
316 ADJUST DENSITY – "Linear" level mode 162
ADJUST DENSITY – "Height linearized" level mode 175
ADJUST DENSITY– "Level" extended setup 184
317 CUST. UNIT. FACT. P 145, 147, 151, 156 or 180
318 TEMP. ENG. UNIT – "Pressure" measuring mode 183
TEMP. ENG. UNIT – "Level" measuring mode 184
TEMP. ENG. UNIT – "Flow" measuring mode 185
319 CALIB. OFFSET 143
323 SET. L. FL. CUT-OFF 185
329 FACT. U.U. TOTAL.1 193
330 FACT. U.U. TOTAL.2 194
331 RESET TOTALIZER 1 193
332 Pmin ALARM WINDOW 208
333 Pmax ALARM WINDOW 208