Liquiphant FTL64 HART Mounting
Endress+Hauser 15
A0042345
 8 Installation examples for a highly viscous process medium
5.1.5 Take clearance into consideration
Allow sufficient space outside the tank for mounting, connection and settings involving
the electronic insert.
A0042340
 9 Take clearance into consideration
5.1.6 Support the device
NOTICE
If the device is supported incorrectly, shocks and vibrations can damage the coated
surface.
Only use suitable supports.
Support the device in the event of severe dynamic load. Maximum lateral loading capacity
of the pipe extensions and sensors: 75 Nm (55 lbf ft).