Mounting Liquiphant FTL64 HART
16 Endress+Hauser
A0042356
 10 Examples of support in the event of dynamic load
Marine approval: In the case of pipe extensions or sensors longer than 1 600 mm, a
support is needed at least every 1 600 mm.
5.2 Mounting the device
5.2.1 Required tool
Open-ended wrench for sensor installation
Allen key for housing locking screw
5.2.2 Installation
Aligning the tuning fork using the marking
The tuning fork can be aligned using the marking. Medium can thus run off easily and
buildup is avoided.
Markings may include the following:
Material information, thread name or circle on the hexagonal nut
II symbol on the back of the flange
316L/G1
A0042348
 11 Markings to align the tuning fork