Operation Liquistation CSF34
118 Endress+Hauser
Possible application --> For outputting a manipulated variable to connected actuators
The binary output must be assigned in the program or subprogram before it can be
activated.
Menu/Setup/Outputs
Function Options Info
OutputBinary
Function Selection
Off
Event
Limit value
Diagnostics message
Cleaning
(Only for version with
sensors with Memosens
protocol)
Factory setting
Off
The following functions depend on the
option selected. Function = "Off" switches off
the function of the binary output and means
no further settings are required.
For Cleaning:
The outputs can only switch 100mA. A
relay must be added to control valves
or motors.
If you select Function Event
Signal slope Selection
Low-High
High-Low
Factory setting
Low-High
Select the level change of the signal