The "Expert" menu Micropilot FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/FMR57 FOUNDATION Fieldbus
100 Endress+Hauser
Partial mapping / Deleting a map partially
The overlaying or new recording of the map does not necessarily cover the complete
measuring range. Instead a partial mapping can be performed.
The mapping starts at –0.25 m (–0.8 ft), i.e. above the reference point.
The end point of the mapping range can be defined in the Mapping end point
parameter.
After these settings, the recording of the mapping curve is started as decribed above.
The map can also be partially deleted. This is performed as follows:
1. Enter the end point of the area to be deleted into the Mapping end point parameter.
2. Go to the Record map parameter and select the Delete partial map option.