The "Expert" menu Micropilot FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/FMR57 FOUNDATION Fieldbus
36 Endress+Hauser
Further parameters
Activate SW option (0029)
Navigation Expert → System → Administration → Activate SW option
Write access Maintenance
Description Enter a code to activate specific software options.
Device reset (1013)
Navigation Expert → System → Administration → Device reset
Write access Maintenance
Description Use this function to reset the device configuration - either entirely or in part - to a defined
state.
Options Cancel
No action is executed and the user exits the parameter.
To factory defaults
Every parameter is reset to the order-code specific factory setting.
To delivery settings
Every parameter is reset to the delivery setting. The delivery setting may differ from the
factory default if customer specific settings have been ordered.
Of customer settings
Every customer parameter is reset to its factory setting. Service parameters, however,
retain their current value.
To transducer defaults
Every measurment-related parameter is reset to its factory setting. Service parameters
and communication-related parameters, however, retain their current value.
Restart device
The restart resets every parameter whose data are in the volatile memory (RAM) to the
factory setting (e.g. measured value data). The device configuration is not modified.
Factory setting Cancel
Additional information To delivery settings
This option is only visible if customer-specific settings have been ordered.