The "Expert" menu Micropilot FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/FMR57 FOUNDATION Fieldbus
58 Endress+Hauser
Additional information None
The level is transmitted in the level unit without linearization.
Linear
The output value (volume/weight) is directly proportional to the level L. This is valid, for
example, for vertical cylinders. Additionally, the following parameters have to be
specified:
Unit after linearization (2340)
Maximum value (2315): Maximum volume or weight
Table
The relationship between the measured level L and the output value (volume/weight) is
given by a linearization table consisting of up to 32 pairs of values "level - volume" or
"level - weight", respectively.
Additionally, the following parameters have to be specified:
Unit after linearization (2340)
Table mode (2303)
For each table point: Level (2383)
For each table point: Customer value (2384)
Activate table (2304)
Pyramid bottom
The output value corresponds to the volume or weight in a silo with pyramid bottom.
Additionally, the following parameters have to be specified:
Unit after linearization (2340)
Maximum value (2315): Maximum volume or weight
Intermediate height (2310): The height of the pyramid
Conical bottom
The output value corresponds to the volume or weight in a tank with conical bottom.
Additionally, the following parameters have to be specified:
Unit after linearization (2340)
Maximum value (2315): Maximum volume or weight
Intermediate height (2310): The height of the conical part of the tank
Angled bottom
The output value corresponds to the volume or weight in a silo with an angled bottom.
Additionally, the following parameters have to be specified:
Unit after linearization (2340)
Maximum value (2315): Maximum volume or weight
Intermediate height (2310): Height of the angled bottom
Horizontal cylinder
The output value corresponds to the volume or weight in a horizontal cylinder tank.
Additionally, the following parameters have to be specified:
Unit after linearization (2340)
Maximum value (2315): Maximum volume or weight
Diameter (2342)
Sphere
The output value corresponds to the volume or weight in a spherical tank. Additionally,
the following parameters have to be specified:
Unit after linearization (2340)
Maximum value (2315): Maximum volume or weight
Diameter (2342)
Unit after linearization (2340)
Navigation Expert → Sensor → Linearization → Unit after linearization
Write access Maintenance

Table of Contents