Wiring Proline Promag 10
34 Endress+Hauser
3 Wiring
#
Warning!
Risk of electric shock! Components carry dangerous voltages.
Never mount or wire the measuring device while it is connected to the power supply.
Before connecting the power supply, check the safety equipment.
Route the power supply and signal cables so they are securely seated.
Seal the cable entries and covers tight.
"
Caution!
Risk of damaging the electronic components!
Connect the power supply in accordance with the connection data on the nameplate.
Connect the signal cable in accordance with the connection data in the Operating Instructions
or the Ex documentation on the CD-ROM.
In addition, for the remote version:
"
Caution!
Risk of damaging the electronic components!
Only connect sensors and transmitters with the same serial number.
Observe the cable specifications of the connecting cable Operating Instructions on the
CD-ROM.
Note! Install the connecting cable securely to prevent movement.
In addition, for measuring devices with fieldbus communication:
"
Caution!
Risk of damaging the electronic components!
Observe the cable specification of the fieldbus cable Operating Instructions on the
CD-ROM.
Keep the stripped and twisted lengths of cable shield as short as possible.
Screen and ground the signal lines Operating Instructions on the CD-ROM.
When using in systems without potential equalization Operating Instructions on the
CD-ROM.
In addition, for Ex-certified measuring devices:
#
Warning!
When wiring Ex-certified measuring devices, all the safety instructions, wiring diagrams,
technical information etc. of the related Ex documentation must be observed Ex
documentation on the CD-ROM.