Proline Promag 50H, 53H
Endress+Hauser 27
For order codes with suffixes +CA/+CB:
A0021198-EN
Medium pressure range
(nominal pressure)
The permitted nominal pressure depends on the process connection, the seal and the nominal
diameter:
Process connections DN 2 to 25 (¹⁄₁₂ to 1") with O-ring seal
Process connections DN 2 to 25 (¹⁄₁₂ to 1") with aseptic gasket seal
0
5
10
15
20
25
30
[bar][psi]
-40
-20
020
40 60 80 100 140 180 [°C]
360 [°F]
0-40 100 200 300
200
100
400
300
0
PN25: )DN40(1 ½"
120 160
PN16:DN 50...100( )2...4"
PN10:DN 125...150( )5...6"
Nominal diameter [mm] 2 4 8 15 25
[inch] ¹⁄₁₂" ¹⁄₈" ³⁄₈" ½" 1"
Weld sockets: DIN EN ISO 1127, ODT/SMS
1.4404 (316L): PN 40 (580 psi)
Couplings: ISO 228/DIN 2999, NPT
Flange: EN 1092-1 (DIN 2501) 1.4404 (316L): PN 40 (580 psi),
PVDF: PN 16 (232 psi)
Flange: ASME B16.5 1.4404 (316L), PVDF: Class 150
Flange: JIS B2220 1.4404 (316L): 20 K, PVDF: 10 K
Hose connection 1.4404 (316L): PN 16 (232 psi)
PVC adhesive fitting PVC: PN 16 (232 psi)
Nominal diameter [mm] 2 4 8 15 25
[inch] ¹⁄₁₂" ¹⁄₈" ³⁄₈" ½" 1"
Weld sockets: EN 10357 (DIN 11850), ODT/SMS
1.4404 (316L): PN 16 (232 psi)
Couplings: SC DIN 11851, DIN 11864-1, SMS 1145
Clamp: ISO 2852/Fig. 2, DIN 32676, L14 AM7
Flange: DIN 11864-2