EasyManua.ls Logo

Endress+Hauser Proline Promag 53H - Pressure Tightness; Limiting Flow; Pressure Loss

Endress+Hauser Proline Promag 53H
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Promag 50H, 53H
28 Endress+Hauser
Process connections DN 40 to 150 (1½ to 6") with aseptic gasket seal 1.4404 (F316L)
Pressure tightness Measuring tube lining: PFA
Limiting flow The diameter of the pipe and the flow rate determine the nominal diameter of the sensor.
The optimum flow velocity is between 2 and 3 m/s (6.5 to 9.8 ft/s). Also match the velocity of flow (v)
to the physical properties of the fluid:
v < 2 m/s (6.5 ft/s): For low conductivity values
v > 2 m/s (6.5 ft/s): For media that produce buildup (e.g. milk with high fat content)
!
Note!
A necessary increase in the flow velocity can be achieved by reducing the sensor nominal diameter
( 18, Section "Adapters").
•For uids with high levels of solids, the selection of a pipe with nominal diameter > DN 8 (³") may
be considered, to improve the stability of the signal and cleanability due to larger electrodes.
Pressure loss With nominal diameters from DN 8 (³") no pressure loss if the sensor is installed in a pipe with the
same nominal diameter.
Pressure losses for configurations incorporating adapters according to DIN EN 545 (
18, Section "Adapters").
Nominal diameter [mm] 40 50 65 80 100 125 150
[inch] 1½" 2" - 3" 4" - 6"
Weld socket: ODT/SMS PN 16 (232 psi)
Weld socket: EN 10357 (DIN 11850) PN 16 (232 psi)
For order codes with suffixes +CA/
+CB
PN 40
(580 psi)
PN 25 (362.5 psi) PN 16
(232 psi)
Weld socket: ISO 2037 PN 40
(580 psi)
PN 25 (362.5 psi) PN16 (232 psi)
Weld socket: ASME BPE PN 40
(580 psi)
PN 25 (362.5 psi) - PN 16
(232 psi)
Clamp: ISO 2852, DIN 32676, L14 AM7 PN 16 (232 psi) PN 10 (145 psi)
Coupling: SC DIN 11851 PN 16 (232 psi)
For order codes with suffixes +CA/
+CB
PN 40
(580 psi)
PN 25 (362.5 psi) PN 16 (232 psi)
Coupling: SMS 1145 PN 16 (232 psi)
Coupling: DIN 11864-1, ISO 2853 PN 16 (232 psi)
For order codes with suffixes +CA/
+CB
PN 40
(580 psi)
PN 25 (362.5 psi) -
Flange: DIN 11864-2 PN 16 (232 psi)
For order codes with suffixes +CA/
+CB
PN 25
(362.5
psi)
PN 16 (232 psi) PN 10 (145 psi)
Nominal diameter Limit values for abs. pressure [mbar] ([psi]) at fluid temperatures:
[mm] [inch] 25 °C
(77 °F)
80 °C
(176 °F)
100 °C
(212 °F)
130 °C
(266 °F)
150 °C
(302 °F)
2 to 150 ¹ to 6"00000